DC-Surge protection T1/2 with MC4

DC-Surge protection T1/2 with MC4

Number of MPP trackers

  • 7720001
  • DCT17YMC
  • 4034338651067
  • 1 / 14 / 224
Product information "DC-Surge protection T1/2 with MC4"
Surge protection connection box for PV inverters, DC side, type 1+2, 1100V, for 3 MPPT, with MC4 connectors, protection class IP67

Properties
Height: 190 mm
Width: 225 mm
Depth: 91 mm
Number of MPP trackers: 3
DC-Protection: Type 1/2
Degree of protection (IP): IP67
Type of cable feed: MC4
REACH: false
RoHS: true
Protection against thermal overload: true
Function/defect display: Signal indicator green / not green
Housing material: Polycarbonate with semi-transparent cover
Installation type: Wall - Indoor/Outdoor
Protection level (2MC4 variant) Up: 4400
Permissible humidity RH: 5%...95%
Protective conductor current (AC /DC) Ipe: <1mA / <50 µA
Maximum leakage surge current (8/20µs) Imax: 40 kA
Rated leakage surge current (8/20µs) In: 20
Highest continuous voltage (DC) Ucpv: 1100 V
Total lightning impulse current I Total (8/20) / I Total (10/350): 50 kA / 12,5 kA
Continuous operating current (DC) Icpv: <50 µA
Operating temperature range Ta: -40 °C to +85 °C
Lightning impulse current Iimp (10/350): 6,25